the conversion procedure is simple: - find all things that look like options, ie calls to either `mkOption` or `lib.mkOption` that take an attrset. remember the attrset as the option - for all options, find a `description` attribute who's value is not a call to `mdDoc` or `lib.mdDoc` - textually convert the entire value of the attribute to MD with a few simple regexes (the set from mdize-module.sh) - if the change produced a change in the manual output, discard - if the change kept the manual unchanged, add some text to the description to make sure we've actually found an option. if the manual changes this time, keep the converted description this procedure converts 80% of nixos options to markdown. around 2000 options remain to be inspected, but most of those fail the "does not change the manual output check": currently the MD conversion process does not faithfully convert docbook tags like <code> and <package>, so any option using such tags will not be converted at all.
192 lines
6.2 KiB
Nix
192 lines
6.2 KiB
Nix
{ config, lib, pkgs, ... }:
|
|
|
|
with lib;
|
|
|
|
let
|
|
cfg = config.services.apcupsd;
|
|
|
|
configFile = pkgs.writeText "apcupsd.conf" ''
|
|
## apcupsd.conf v1.1 ##
|
|
# apcupsd complains if the first line is not like above.
|
|
${cfg.configText}
|
|
SCRIPTDIR ${toString scriptDir}
|
|
'';
|
|
|
|
# List of events from "man apccontrol"
|
|
eventList = [
|
|
"annoyme"
|
|
"battattach"
|
|
"battdetach"
|
|
"changeme"
|
|
"commfailure"
|
|
"commok"
|
|
"doreboot"
|
|
"doshutdown"
|
|
"emergency"
|
|
"failing"
|
|
"killpower"
|
|
"loadlimit"
|
|
"mainsback"
|
|
"onbattery"
|
|
"offbattery"
|
|
"powerout"
|
|
"remotedown"
|
|
"runlimit"
|
|
"timeout"
|
|
"startselftest"
|
|
"endselftest"
|
|
];
|
|
|
|
shellCmdsForEventScript = eventname: commands: ''
|
|
echo "#!${pkgs.runtimeShell}" > "$out/${eventname}"
|
|
echo '${commands}' >> "$out/${eventname}"
|
|
chmod a+x "$out/${eventname}"
|
|
'';
|
|
|
|
eventToShellCmds = event: if builtins.hasAttr event cfg.hooks then (shellCmdsForEventScript event (builtins.getAttr event cfg.hooks)) else "";
|
|
|
|
scriptDir = pkgs.runCommand "apcupsd-scriptdir" { preferLocalBuild = true; } (''
|
|
mkdir "$out"
|
|
# Copy SCRIPTDIR from apcupsd package
|
|
cp -r ${pkgs.apcupsd}/etc/apcupsd/* "$out"/
|
|
# Make the files writeable (nix will unset the write bits afterwards)
|
|
chmod u+w "$out"/*
|
|
# Remove the sample event notification scripts, because they don't work
|
|
# anyways (they try to send mail to "root" with the "mail" command)
|
|
(cd "$out" && rm changeme commok commfailure onbattery offbattery)
|
|
# Remove the sample apcupsd.conf file (we're generating our own)
|
|
rm "$out/apcupsd.conf"
|
|
# Set the SCRIPTDIR= line in apccontrol to the dir we're creating now
|
|
sed -i -e "s|^SCRIPTDIR=.*|SCRIPTDIR=$out|" "$out/apccontrol"
|
|
'' + concatStringsSep "\n" (map eventToShellCmds eventList)
|
|
|
|
);
|
|
|
|
in
|
|
|
|
{
|
|
|
|
###### interface
|
|
|
|
options = {
|
|
|
|
services.apcupsd = {
|
|
|
|
enable = mkOption {
|
|
default = false;
|
|
type = types.bool;
|
|
description = lib.mdDoc ''
|
|
Whether to enable the APC UPS daemon. apcupsd monitors your UPS and
|
|
permits orderly shutdown of your computer in the event of a power
|
|
failure. User manual: http://www.apcupsd.com/manual/manual.html.
|
|
Note that apcupsd runs as root (to allow shutdown of computer).
|
|
You can check the status of your UPS with the "apcaccess" command.
|
|
'';
|
|
};
|
|
|
|
configText = mkOption {
|
|
default = ''
|
|
UPSTYPE usb
|
|
NISIP 127.0.0.1
|
|
BATTERYLEVEL 50
|
|
MINUTES 5
|
|
'';
|
|
type = types.lines;
|
|
description = lib.mdDoc ''
|
|
Contents of the runtime configuration file, apcupsd.conf. The default
|
|
settings makes apcupsd autodetect USB UPSes, limit network access to
|
|
localhost and shutdown the system when the battery level is below 50
|
|
percent, or when the UPS has calculated that it has 5 minutes or less
|
|
of remaining power-on time. See man apcupsd.conf for details.
|
|
'';
|
|
};
|
|
|
|
hooks = mkOption {
|
|
default = {};
|
|
example = {
|
|
doshutdown = "# shell commands to notify that the computer is shutting down";
|
|
};
|
|
type = types.attrsOf types.lines;
|
|
description = lib.mdDoc ''
|
|
Each attribute in this option names an apcupsd event and the string
|
|
value it contains will be executed in a shell, in response to that
|
|
event (prior to the default action). See "man apccontrol" for the
|
|
list of events and what they represent.
|
|
|
|
A hook script can stop apccontrol from doing its default action by
|
|
exiting with value 99. Do not do this unless you know what you're
|
|
doing.
|
|
'';
|
|
};
|
|
|
|
};
|
|
|
|
};
|
|
|
|
|
|
###### implementation
|
|
|
|
config = mkIf cfg.enable {
|
|
|
|
assertions = [ {
|
|
assertion = let hooknames = builtins.attrNames cfg.hooks; in all (x: elem x eventList) hooknames;
|
|
message = ''
|
|
One (or more) attribute names in services.apcupsd.hooks are invalid.
|
|
Current attribute names: ${toString (builtins.attrNames cfg.hooks)}
|
|
Valid attribute names : ${toString eventList}
|
|
'';
|
|
} ];
|
|
|
|
# Give users access to the "apcaccess" tool
|
|
environment.systemPackages = [ pkgs.apcupsd ];
|
|
|
|
# NOTE 1: apcupsd runs as root because it needs permission to run
|
|
# "shutdown"
|
|
#
|
|
# NOTE 2: When apcupsd calls "wall", it prints an error because stdout is
|
|
# not connected to a tty (it is connected to the journal):
|
|
# wall: cannot get tty name: Inappropriate ioctl for device
|
|
# The message still gets through.
|
|
systemd.services.apcupsd = {
|
|
description = "APC UPS Daemon";
|
|
wantedBy = [ "multi-user.target" ];
|
|
preStart = "mkdir -p /run/apcupsd/";
|
|
serviceConfig = {
|
|
ExecStart = "${pkgs.apcupsd}/bin/apcupsd -b -f ${configFile} -d1";
|
|
# TODO: When apcupsd has initiated a shutdown, systemd always ends up
|
|
# waiting for it to stop ("A stop job is running for UPS daemon"). This
|
|
# is weird, because in the journal one can clearly see that apcupsd has
|
|
# received the SIGTERM signal and has already quit (or so it seems).
|
|
# This reduces the wait time from 90 seconds (default) to just 5. Then
|
|
# systemd kills it with SIGKILL.
|
|
TimeoutStopSec = 5;
|
|
};
|
|
unitConfig.Documentation = "man:apcupsd(8)";
|
|
};
|
|
|
|
# A special service to tell the UPS to power down/hibernate just before the
|
|
# computer shuts down. (The UPS has a built in delay before it actually
|
|
# shuts off power.) Copied from here:
|
|
# http://forums.opensuse.org/english/get-technical-help-here/applications/479499-apcupsd-systemd-killpower-issues.html
|
|
systemd.services.apcupsd-killpower = {
|
|
description = "APC UPS Kill Power";
|
|
after = [ "shutdown.target" ]; # append umount.target?
|
|
before = [ "final.target" ];
|
|
wantedBy = [ "shutdown.target" ];
|
|
unitConfig = {
|
|
ConditionPathExists = "/run/apcupsd/powerfail";
|
|
DefaultDependencies = "no";
|
|
};
|
|
serviceConfig = {
|
|
Type = "oneshot";
|
|
ExecStart = "${pkgs.apcupsd}/bin/apcupsd --killpower -f ${configFile}";
|
|
TimeoutSec = "infinity";
|
|
StandardOutput = "tty";
|
|
RemainAfterExit = "yes";
|
|
};
|
|
};
|
|
|
|
};
|
|
|
|
}
|