mirror of
https://github.com/embassy-rs/embassy.git
synced 2024-11-21 14:22:33 +00:00
time-driver: clarify docs for set_alarm.
This commit is contained in:
parent
1ea29f1d2e
commit
d193c9ef44
@ -113,24 +113,52 @@ pub trait Driver: Send + Sync + 'static {
|
||||
/// It is UB to make the alarm fire before setting a callback.
|
||||
unsafe fn allocate_alarm(&self) -> Option<AlarmHandle>;
|
||||
|
||||
/// Sets the callback function to be called when the alarm triggers.
|
||||
/// Set the callback function to be called when the alarm triggers.
|
||||
/// The callback may be called from any context (interrupt or thread mode).
|
||||
fn set_alarm_callback(&self, alarm: AlarmHandle, callback: fn(*mut ()), ctx: *mut ());
|
||||
|
||||
/// Sets an alarm at the given timestamp. When the current timestamp reaches the alarm
|
||||
/// timestamp, the provided callback function will be called.
|
||||
/// Set an alarm at the given timestamp.
|
||||
///
|
||||
/// The `Driver` implementation should guarantee that the alarm callback is never called synchronously from `set_alarm`.
|
||||
/// Rather - if `timestamp` is already in the past - `false` should be returned and alarm should not be set,
|
||||
/// or alternatively, the driver should return `true` and arrange to call the alarm callback as soon as possible, but not synchronously.
|
||||
/// There is a rare third possibility that the alarm was barely in the future, and by the time it was enabled, it had slipped into the
|
||||
/// past. This is can be detected by double-checking that the alarm is still in the future after enabling it; if it isn't, `false`
|
||||
/// should also be returned to indicate that the callback may have been called already by the alarm, but it is not guaranteed, so the
|
||||
/// caller should also call the callback, just like in the more common `false` case. (Note: This requires idempotency of the callback.)
|
||||
/// ## Behavior
|
||||
///
|
||||
/// When callback is called, it is guaranteed that now() will return a value greater or equal than timestamp.
|
||||
/// If `timestamp` is in the future, `set_alarm` schedules calling the callback function
|
||||
/// at that time, and returns `true`.
|
||||
///
|
||||
/// Only one alarm can be active at a time for each AlarmHandle. This overwrites any previously-set alarm if any.
|
||||
/// If `timestamp` is in the past, `set_alarm` has two allowed behaviors. Implementations can pick whether to:
|
||||
///
|
||||
/// - Schedule calling the callback function "immediately", as if the requested timestamp was "now+epsilon" and return `true`, or
|
||||
/// - Not schedule the callback, and return `false`.
|
||||
///
|
||||
/// Callers must ensure to behave correctly with either behavior.
|
||||
///
|
||||
/// When callback is called, it is guaranteed that `now()` will return a value greater than or equal to `timestamp`.
|
||||
///
|
||||
/// ## Reentrancy
|
||||
///
|
||||
/// Calling the callback from `set_alarm` synchronously is not allowed. If the implementation chooses the first option above,
|
||||
/// it must still call the callback from another context (i.e. an interrupt handler or background thread), it's not allowed
|
||||
/// to call it synchronously in the context `set_alarm` is running.
|
||||
///
|
||||
/// The reason for the above is callers are explicitly permitted to do both of:
|
||||
/// - Lock a mutex in the alarm callback.
|
||||
/// - Call `set_alarm` while having that mutex locked.
|
||||
///
|
||||
/// If `set_alarm` called the callback synchronously, it'd cause a deadlock or panic because it'd cause the
|
||||
/// mutex to be locked twice reentrantly in the same context.
|
||||
///
|
||||
/// ## Overwriting alarms
|
||||
///
|
||||
/// Only one alarm can be active at a time for each `AlarmHandle`. This overwrites any previously-set alarm if any.
|
||||
///
|
||||
/// ## Unsetting the alarm
|
||||
///
|
||||
/// There is no `unset_alarm` API. Instead, callers can call `set_alarm` with `timestamp` set to `u64::MAX`.
|
||||
///
|
||||
/// This allows for more efficient implementations, since they don't need to distinguish between the "alarm set" and
|
||||
/// "alarm not set" cases, thanks to the fact "Alarm set for u64::MAX" is effectively equivalent for "alarm not set".
|
||||
///
|
||||
/// This means implementations need to be careful to avoid timestamp overflows. The recommendation is to make `timestamp`
|
||||
/// be in the same units as hardware ticks to avoid any conversions, which makes avoiding overflow easier.
|
||||
fn set_alarm(&self, alarm: AlarmHandle, timestamp: u64) -> bool;
|
||||
}
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user