mirror of
https://github.com/PAMGuard/PAMGuard.git
synced 2024-11-21 22:52:22 +00:00
added help details server connection & calibration
This commit is contained in:
parent
d05cecaf8b
commit
3f2e4239b0
@ -25,28 +25,232 @@
|
|||||||
export to Tethys. </p>
|
export to Tethys. </p>
|
||||||
|
|
||||||
|
|
||||||
|
<h3> Connection and Project Details </h3>
|
||||||
|
|
||||||
<h3>Tethys Server</h3>
|
<p>
|
||||||
<p>Make sure you have a <a href = "tethys_server.html">Tethys Server</a> running. The PAMGuard interface will
|
Make sure you have a <a href = "tethys_server.html">Tethys Server</a> running. The PAMGuard interface will
|
||||||
only work with <a href="https://tethys.sdsu.edu/tethys3/">Tethys 3.</a> </p>
|
only work with <a href="https://tethys.sdsu.edu/tethys3/">Tethys
|
||||||
<p>Check the server connection. If PAMGuard has correctly connected to the Tethys server, the top panel of the display will be a normal
|
3</a> or later. The section below specifies how to set the
|
||||||
grey colour. If the connection cannot be made, the panel will be orange.</p>
|
address of Tethys server address as well as determine if
|
||||||
<p>If required, change the server settings using the "Select Sever" button</p>
|
PAMGuard can communicate successfully with Tethys. (The top
|
||||||
|
panel will be orange if communication is not working.
|
||||||
|
</p>
|
||||||
|
|
||||||
|
<h4>Tethys Server</h4>
|
||||||
|
|
||||||
|
|
||||||
|
<p>
|
||||||
|
The Tethys Server field next to the picture of the goddess Tethys
|
||||||
|
indicates the address of the Tehtys server. To change this field,
|
||||||
|
click on the gear icon. You will be prompted to provide a computer
|
||||||
|
address (URL) and a port. The address should start with http://
|
||||||
|
followed by the machine name or internet protocol address unless
|
||||||
|
the Tethys server has been configured to use an encrypted
|
||||||
|
connection. In this case, start the address with https://.
|
||||||
|
</p>
|
||||||
|
|
||||||
|
<p>
|
||||||
|
By default, PAMGuard will use http://localhost:9779 which
|
||||||
|
assumes that your Tethys server is running on the same computer as
|
||||||
|
PAMGuard and that it expects communication on port 9779, the
|
||||||
|
default port (administrators may change this).
|
||||||
|
</p>
|
||||||
|
|
||||||
|
<p>
|
||||||
|
If PAMGuard can communicate with the Tethys server, the
|
||||||
|
Connection and Project panel will be light grey. If
|
||||||
|
communication is not possible, the panel will be colored
|
||||||
|
orange. Likely causes for communication failure are:
|
||||||
|
</p>
|
||||||
|
<ul>
|
||||||
|
<li>
|
||||||
|
The server address or port is incorrect.
|
||||||
|
</li>
|
||||||
|
|
||||||
|
<li>
|
||||||
|
Tethys has not been started on the server machine. One of the
|
||||||
|
main reasons that we see this is when the administrator has
|
||||||
|
not configured Tethys to run automatically as a service. In
|
||||||
|
that case, when a machine reboots (e.g., for automatic
|
||||||
|
operaing system updates) the server will not start
|
||||||
|
automatically. The Tethys manual explains how to configure
|
||||||
|
Tethys as a service that starts automatically when the machine
|
||||||
|
boots.
|
||||||
|
</li>
|
||||||
|
|
||||||
|
<li>
|
||||||
|
Firewall rules do not permit traffic between the machine
|
||||||
|
executing PAMGuard and the one hosting Tethys on the selected
|
||||||
|
port. If you do not have adminstrative privileges, you will
|
||||||
|
need to contact your support team for help.
|
||||||
|
</li>
|
||||||
|
</ul>
|
||||||
|
|
||||||
<h4>Project and Instrument Information</h4>
|
<h4>Project and Instrument Information</h4>
|
||||||
<p>Either select an existing "Project", or create a new one.</p>
|
|
||||||
<p>You also need to give Tethys more information about the instrument(s) or arrays you've deployed than in previous PAMGuard versions. Again, select an
|
<p>
|
||||||
existing instrument, or set up a new one. You'll notice that this information is held with the rest of the PAMGuard array management information.</p>
|
Projects are names used by Tethys to help track work that should
|
||||||
|
be considered together, such as a series of deployments designed
|
||||||
|
to answer a specific question or funded under a specific
|
||||||
|
grant. If you do not already have a project defined in your
|
||||||
|
PAMGuard database, you can click the "New Project" button in the
|
||||||
|
"Connection and Project details" section of the Tethys
|
||||||
|
module. This will start a dialog that asks for a case-sensitive
|
||||||
|
project name and a geographic region. The geographic region is
|
||||||
|
for convenience, PAMGuard and Tethys track information by
|
||||||
|
longitude and latitude, but sometimes it is helpful to query for
|
||||||
|
information with respect to a geographic name such as Channel
|
||||||
|
Islands National Marine Sanctuary.
|
||||||
|
</p>
|
||||||
|
|
||||||
|
<p>
|
||||||
|
The array instrumentation is selected from a drop-down menu next
|
||||||
|
to the Instruments label. A dropdown menu next to the label
|
||||||
|
“Instruments” shows the list of hydrophone arrays. These are
|
||||||
|
likely to have been previously established prior to starting
|
||||||
|
analysis of your data by using the menu Settings -> Hydrophone
|
||||||
|
Array.
|
||||||
|
|
||||||
|
</p>
|
||||||
|
|
||||||
|
<p>
|
||||||
|
If you are a long-time user of PAMGuard, you will notice
|
||||||
|
additional fields are required for instrumentation: Instrument
|
||||||
|
Type and Instrument Id. The type indicates what type of
|
||||||
|
instrument is being used and may be generic such as a mooring or
|
||||||
|
array or denote a specific instrument such as a HARP, Rock
|
||||||
|
Hopper, SoundTrap, etc. The Id is a unique identifier for the
|
||||||
|
instrument such as a serial number. Note that if you are using
|
||||||
|
an older PAMGuard database, you may see a blank entry in the
|
||||||
|
instruments list as these new fields will not have been
|
||||||
|
populated. Press new/edit to access the instrument settings
|
||||||
|
from the Tethys module page.
|
||||||
|
</p>
|
||||||
|
|
||||||
<h3>Data Export</h3>
|
<h3>Data Export</h3>
|
||||||
<p>It's best to export data in the sequence the panels are laid out in on the PAMGuard display, i.e. Calibrations, then Deployments, and finally Detections.</p>
|
|
||||||
|
|
||||||
<h4>Calibrations</h4>
|
<p>
|
||||||
<p>To export the calibration data, press the "Export..." button at the top of the "Instrument Calibration Information" panel.
|
It is best to export data in the sequence the panels are laid out in on the PAMGuard display:
|
||||||
<p>Most of the calibration data is taken from the array manager and from the sound acquisition module. However, PAMGuard will ask a few questions about
|
</p>
|
||||||
HOW the instrument was calibrated, when it was done and who is responsible. Fill in as much information as you can!
|
|
||||||
IF the export is successful, a record will show for each hydrophone (or sensor) in your instrument array in the calibration information table:</p>
|
<ol>
|
||||||
|
<li>
|
||||||
|
Instrument calibration information: exports to the Tethys Calibrations
|
||||||
|
</li>
|
||||||
|
|
||||||
|
<li>
|
||||||
|
Recording periods and deployment information: exports to Tethys Deployments
|
||||||
|
</li>
|
||||||
|
|
||||||
|
<li>
|
||||||
|
PAMGuard data blocks: exports to Tethys Detections and/or Localizations.
|
||||||
|
</li>
|
||||||
|
</ol>
|
||||||
|
|
||||||
|
|
||||||
|
<h4>Instrument calibration information</h4>
|
||||||
|
|
||||||
|
<p>
|
||||||
|
Most of the calibration data is taken from the array manager and
|
||||||
|
from the sound acquisition module. However, PAMGuard will ask a
|
||||||
|
few questions about HOW the instrument was calibrated, when it
|
||||||
|
was done and who is responsible.
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
There are two dialogs associated with calibration. The first
|
||||||
|
asks for a calibration method and has the following fields:
|
||||||
|
</p>
|
||||||
|
<ul>
|
||||||
|
<li>
|
||||||
|
Method: Must be one of the following options:
|
||||||
|
<ul>
|
||||||
|
<li>Reference hydrophone</li>
|
||||||
|
<li>Manufacturer’s specification</li>
|
||||||
|
<li>Piston phone</li>
|
||||||
|
<li>Other calibrated source</li>
|
||||||
|
<li>Unknown</li>
|
||||||
|
</ul>
|
||||||
|
</li>
|
||||||
|
|
||||||
|
<li>
|
||||||
|
Serial number: Hydrophone serial number
|
||||||
|
</li>
|
||||||
|
|
||||||
|
<li>
|
||||||
|
Quality: Quality assurance value:
|
||||||
|
<ul>
|
||||||
|
<li> unverified: The calibration has not been verified </li>
|
||||||
|
<li> valid: The calibration has been validated as per the quality assurance process </li>
|
||||||
|
<li> invalid: The calibration was found to be invalid during quality assurance </li>
|
||||||
|
</ul>
|
||||||
|
</li>
|
||||||
|
|
||||||
|
<li>
|
||||||
|
QA Comment: Textual description of the quality assurance
|
||||||
|
process.
|
||||||
|
</li>
|
||||||
|
|
||||||
|
|
||||||
|
<li>
|
||||||
|
Calibration method: Textual description of the Method.
|
||||||
|
</li>
|
||||||
|
</ul>
|
||||||
|
|
||||||
|
<p>
|
||||||
|
The second calibrations dialog asks for:
|
||||||
|
</p>
|
||||||
|
|
||||||
|
<ul>
|
||||||
|
<li>
|
||||||
|
Calibration date: Date the calibration was performed.
|
||||||
|
</li>
|
||||||
|
|
||||||
|
<li>
|
||||||
|
Update frequency: Must be one of the following:
|
||||||
|
<ul>
|
||||||
|
<li>
|
||||||
|
as-needed: No updates are planned, but if a change is needed the calibration will be updated (defaul)t
|
||||||
|
</li>
|
||||||
|
<li>
|
||||||
|
unplanned: There are no plans to ever update the record.
|
||||||
|
</li>
|
||||||
|
<li>
|
||||||
|
yearly: A yearly review will be conducted to ensure that the record is valid.
|
||||||
|
</li>
|
||||||
|
</ul>
|
||||||
|
</li>
|
||||||
|
|
||||||
|
<li>
|
||||||
|
Technical Person / Data Manager: These two types of data have
|
||||||
|
the same fields and detail who was responsible for the
|
||||||
|
calibration and who is responsible for maintaining the record
|
||||||
|
of the calibration. In many cases, this may be the same
|
||||||
|
person and copy buttons allow the fields to be duplicated.
|
||||||
|
|
||||||
|
<ul>
|
||||||
|
<li>
|
||||||
|
Name: Responsible party’s naem
|
||||||
|
</li>
|
||||||
|
<li>
|
||||||
|
Organisation: Organisation to which the party reports
|
||||||
|
</li>
|
||||||
|
<li>
|
||||||
|
Position: Responsible party’s title
|
||||||
|
</li>
|
||||||
|
<li>
|
||||||
|
Email: Email contact information
|
||||||
|
</li>
|
||||||
|
</ul>
|
||||||
|
</li>
|
||||||
|
|
||||||
|
</ul>
|
||||||
|
|
||||||
|
<p>
|
||||||
|
Fill in as much information as you can!
|
||||||
|
If the export is successful, a record will show for each
|
||||||
|
hydrophone (or sensor) in your instrument array in the
|
||||||
|
calibration information table:
|
||||||
|
</p>
|
||||||
|
|
||||||
<center><img src="./images/calibration_information.png"></center>
|
<center><img src="./images/calibration_information.png"></center>
|
||||||
|
|
||||||
@ -55,7 +259,7 @@
|
|||||||
<a href="../../generalDatabaseHelp/docs/database_database.html">PAMGuard database</a> and
|
<a href="../../generalDatabaseHelp/docs/database_database.html">PAMGuard database</a> and
|
||||||
<a href= "../../BinaryStore/docs/binarystore_overview.html">binary Store</a>. Where data were collected on a regular duty
|
<a href= "../../BinaryStore/docs/binarystore_overview.html">binary Store</a>. Where data were collected on a regular duty
|
||||||
cycle, or continuously, there should be a single record in the table of recording periods. If data were collected on a more
|
cycle, or continuously, there should be a single record in the table of recording periods. If data were collected on a more
|
||||||
"ad-hoc" basis, for instance during a boat based survey, there might be many different records in the table.
|
"ad-hoc" basis, for instance during a boat-based survey, there might be many different records in the table.
|
||||||
Occasionally, there may be short recording periods (e.g. while you were testing kit on deck) that you don't want to export. Either select
|
Occasionally, there may be short recording periods (e.g. while you were testing kit on deck) that you don't want to export. Either select
|
||||||
individual rows that you want to export, or right click on the table and "Select All".</p>
|
individual rows that you want to export, or right click on the table and "Select All".</p>
|
||||||
|
|
||||||
|
Loading…
Reference in New Issue
Block a user